ADVANTAGE |
• Minimum sample volumes
• Perfect for measurement of sweat samples
• Simple operation and handling
• Automatic measuring
• Fast operational readiness
• IVD-control standard in OPC-ampoules
• Comfortably controlled via a touch screen
• Optional built-in printer
• Data transfer via USB or R$232
• Results remain available after switching to stand-by
• Easy to handle and maintain
• No need to correct the factory calibration
|
KEY DATA |
– Sample volume
20 ul
– Duration of measurement
Approx. 20 seconds
– Reproducibility
‡ 2 digits (20 pl) at 100 mmol/1
– Measurement display
0 – 999 mmol/1
– Measurement range
10 – 999 mmol/1
– Resolution
1 mmol/1 over the entire measurement range
– Integrated stirring
Magnetic stir bar PTFE, cylindrical
– Ambient temperature
10-35 °C
– Power source
220 V (‡ 30V), 50/60 Hz, 40 VA, special models 110V. 100V
– Dimensions
220 x 205 x 360 mm (L x W x H)
– Weight
Approx. 5.7 kg
|
APPLICATION |
Cystic Fibrosis
• Only small amounts of sweat are needed
• Ready-to-use electrolyte (acid buffer and stabilization additive); complies with IVD
• Required electrolyte replacement is indicated
• Required electrode cleaning is indicated (frequent source of error)
• Reference solution 100mmol/1; complies with IVD
• GMP-compliant (Rili-Bäk, MPG) qualification and validation in hospitals and cystic fibrosis clinics
Other Applications
• The system is used both in medical laboratory diagnostics and in industry.
• Chloride determination in serum, urine, sweat or other body fluids
• Examination of food products for quality control purposes
• Water analysis of service water and wastewater
• Agricultural and ecological examinations for determination of salt content in soils
• Building material analysis in the production of cement and plaster
|
MEASUREMENT |
The measurement principle is based on coulometric impulse titration as an absolute measurement method, Through automated sample recognition, the measurement proceeds fully automatically after the sample is inserted without the need for manual confirmation by the user.
The end of the titration is determined by the measurement electrodes, which permanently determine the conductivity of the solution. This allows the CM20 chloride meter to be operated quickly and easily without the need for many years of experience in the classic chloride determination method. If the chloride ion concentration is very low, it is possible to raise the concentration using the standard solution.
|
ACCESORIES |
• Printer paper
• Original Gonotec rolls of printer paper
• Standard solution 100 mmol/1, 10x1ml
• Reagent Set for chloride test
• Acid-buffer son. (37x10ml) & stabilizer (1x30ml)
|
Reviews